THEO MA1 Serie | Betriebsparameter

Below is a consolidated reference table covering all current MA1 Series handheld laser welder models (MA1‑35, MA1‑45, MA1‑65, and MA1 ULTRA). These details will aid a Laser Safety Officer (LSO) or safety consultant in designing a safe Class 4 laser work environment: selecting appropriate eyewear, defining barriers/enclosures, managing ventilation, and implementing access control procedures. All data are taken from THEO’s Technical Data MA1 Series (version 1.2).

Laserparameter der MA1-Serie und EU-Sicherheitshinweise #

Laser welding source #

Parameter MA1‑35 MA1‑45 MA1‑65 MA1 ULTRA Wichtige EU-/Sicherheitshinweise
Klassifizierung Class 4 near‑IR fiber laser
Conforms to IEC 60825‑1 / EN 60825‑1
Class 4 lasers demand a laser‑controlled area with door/curtain interlocks, warning signs (ISO 7010), and strict PPE. Comply with EN 60825‑4 for enclosures/guards.
Wavelength 1080 ± 10 nm
Ausgangsleistung Up to 800W Up to 1200W Up to 1500W Up to 2000W All can be adjusted from ~10–100 % of nominal. Even at lower settings, Class 4 hazard remains.
Input power 3000 W 4800 W 6000 W 6000 W
Weld penetration, stainless steel Up to ~3.5 mm Up to ~4.5 mm Up to ~6.5 mm Up to ~8.5 mm Die tatsächliche Durchdringung hängt von der Fahrgeschwindigkeit, dem Schutzgas und den Materialeigenschaften ab.
Weld penetration, steel Up to ~3.5 mm Up to ~4.5 mm Up to ~6.5 mm Up to ~8.5 mm Die tatsächliche Durchdringung hängt von der Fahrgeschwindigkeit, dem Schutzgas und den Materialeigenschaften ab.
Weld penetration, aluminum Up to ~3.0 mm Up to ~4.0 mm Up to ~5.5 mm Up to ~6.5 mm Die tatsächliche Durchdringung hängt von der Fahrgeschwindigkeit, dem Schutzgas und den Materialeigenschaften ab.

General characteristics #

Parameter MA1‑35 MA1‑45 MA1‑65 MA1 ULTRA Wichtige EU-/Sicherheitshinweise
Power supply Single‑phase 200–240 V AC
(~26 A recommended)
Muss die CE-Anforderungen der Niederspannungsrichtlinie (2014/35/EU) und die lokalen elektrischen Normen erfüllen. Eine ordnungsgemäße Erdung ist obligatorisch.
Betriebsumgebungstemperatur 0–40 °C
Relative humidity 10–85 %
Lagertemperatur −10–60 °C
Gewicht 29 ± 3 kg (64 lb) 38 ± 3 kg (84 lb) 39 ± 3 kg (86 lb) 42 ± 3 kg (93 lb)
Dimensions (L × H × W) 577 × 512 × 265 mm 667 × 542 × 276 mm 667 × 542 × 276 mm 667 × 542 × 276 mm
Airborne noise level Max. 85 dB(A)
Fans adjust automatically to the working condition.
For installations within the EU, comply with EN ISO 11553‑3.
Cooling, laser source Luftgekühlt (interne Lüfter) Stellen Sie sicher, dass die Lüftungsöffnungen frei sind. Betriebstemperatur und Luftfeuchtigkeit müssen innerhalb der angegebenen Grenzen bleiben.
Cooling, welding head Gas cooling of the fiber connector and optics

Optical parameters #

Parameter MA1‑35 MA1‑45 MA1‑65 MA1 ULTRA Wichtige EU-/Sicherheitshinweise
Operating mode Continuous‑Wave (CW) fiber laser
May be rapidly gated on/off for tack or “fish‑scale” welds
No Q‑switched or short‑pulse output. Laser is fundamentally CW, which is fully Class 4 at any power setting.
Polarisation Random
Output at 100 % CW 750–800W 1150–1200W 1450–1500W 1900–2000W Ambient temperature 26 °C
Electro‑optical efficiency 27 % 35 % The MA1 ULTRA uses a different diode technology.
Leistungsregelungsbereich 10–100 % 1 %; ambient temperature 26 °C
Raw beam diameter 4.47 mm
Beam diameter at focus point 60 µm
Abweichungswinkel 29.8 mrad
Rayleigh length 2,0 mm
Duty cycle 75 % 75 % 75 % 100 % 75 % ≈ 120 s on / 40 s off
Wobble width range 0–4 mm 0–6 mm* *Available from H2/2026
Maximale Modulationsfrequenz 10 kHz
Laser switch‑off delay (programmable) 0–100 ms
Short‑term power stability 2 % 100 % CW, > 1 h
Collimating lens (QCS) 50 mm Focal length of the collimating lens
Fokus Linse 150 mm Focal length of the focusing lens
Beam quality M² 1.3 (typ.) 100 % CW
Laser activation time (on) 50–100 µs 10–90 % power
Laser switch‑off time 50–100 µs 90–10 % output
Erkennung von Faserbrüchen 100 µs
Displayed power of the red pilot beam 300–1000 µW 100 % CW
NOHD 127 m 156 m 174 m 201 m Eye hazard calculation
MPE, eye (MZB) 70.7 W/m² Based on DIN EN 60825‑1
NHZ 24 m 29 m 33 m 38 m Skin hazard calculation
MPE, skin 2000 W/m² Based on DIN EN 60825‑1
Fiber diameter 20 µm
Length of the hose pack with optical fiber 4.35 m 5.6 m 5.6 m 5.6 m
Bending radius of the fiber hose pack 200 mm
Laserausgangsstecker QCS, integrated fiber

Shielding gas, protective equipment and workplace #

Parameter MA1 Series (all models) Wichtige EU-/Sicherheitshinweise
Shielding gas Argon (Ar) @ 99.996 % purity
Nitrogen (N₂) @ 99.999 % purity
~10–16 l/min (~21–34 cfh)
Argon oder Stickstoff hilft, Oxidation und Spritzer zu reduzieren. Gasversorgung und Druck müssen den örtlichen Gassicherheitsstandards entsprechen.
Laser eye protection >1070–1075 nm → OD6+, D LB6 + IR LB8 + M LB9
>1075–1080 nm → OD6+, D LB6 + IRM LB8
>1080–1087 nm → OD6+, D LB6 + IRM LB7
Check label for wavelength and OD. Use a visor or helmet with IR filter.

PPE must meet EU Regulation 2016/425 and/or ANSI Z136.7 outside the EU.

In the EU, use EN 207 glasses for full protection or EN 208 for alignment.
Barrier / interlock Use laser‑rated enclosures or curtains. Interlock doors recommended (EN 60825‑4). Class 4 lasers require strict access control. Automatic shutdown upon unplanned entry is standard best practice.
Other PPE & clothing – Laser goggles + welding helmet (IR filter)
– Flame‑resistant outerwear/gloves (CE‑approved, e.g. EN ISO 11611 or EN ISO 11612)
Schützt vor direktem/diffusem Strahl, Blendung durch den Schweißbogen, Funken und heißen Spritzern.
Belüftung Local exhaust or filtration recommended (e.g., EN ISO 15012) to manage fumes and airborne particles Laser welding can produce particulates, especially on coated or galvanized metals. Proper ventilation is essential for safety and legal compliance.

T1 wire feeder #

Parameter T1 wire feeder
Power supply 24 V DC
Umgebungsbedingungen No vibration, no bounce
Betriebsumgebungstemperatur 5–50 °C
Luftfeuchtigkeit < 90 % RH
Lagertemperatur −15–85 °C
Dimensions (L × H × W) 580 × 360 × 245 mm
Gewicht 13 ± 3 kg (29 lb)
Maximum wire coil weight 25 kg (55 lb)

For more in-depth specifications, recommended welding settings, and operational guidelines, see the THEO MA1 Operator Manual or contact THEO technical support.

Zertifizierungen und Standards #

Zertifizierung MA1 Series Harmonized standards / basis
EC Declaration of Conformity (CE) In accordance with:
Machinery Directive 2006/42/EC
Low Voltage Directive 2014/35/EU
EMC Directive 2014/30/EU
ISO 12100:2010
ISO 11553‑2:2008
EN 60204‑1:2018
EN 60825‑1:2014+A11:2021
EN IEC 61000‑6‑4:2019
EN IEC 61000‑6‑2:2019
Performance level calculation PL d (third‑party certified, SGS) ISO 13849‑1:2015
Verification of EMC compliance EN IEC 61000‑6‑2:2019
EN IEC 61000‑6‑4:2019
IP protection class IP 54
FCC Supplier’s Declaration of Conformity 47 CFR Part 15 U.S. electromagnetic compatibility
FDA verification of compliance 21 CFR Part 1040.10 U.S. laser safety requirements
Machinery Directive verification of compliance EN ISO 11553‑2:2008
EN ISO 12100:2010
EN 60204‑1:2018
EN 60825‑1:2014+A11:2021
ETL Electrical safety, compatible with UL and CSA standards

Umfassende Sicherheitsmaßnahmen #

  • LOOP-Sicherheitsverriegelung: Der berührungsempfindliche Brenner und die Werkstückklemme verhindern eine versehentliche Aktivierung des Lasers.
  • Zusätzliche Zwei-Kanal-Verriegelung: Erhöht die Sicherheit während des Betriebs. Ermöglicht einen externen Not-Halt über die DB25-Buchse.
  • Schweißbrenner-Auslöser: Sorgt dafür, dass der Laser nur dann feuert, wenn er absichtlich eingeschaltet wird.
  • Gasdruck-Erkennung: Stellt automatisch eine Verbindung zum Steuerschalter her und löst einen Sicherheitsalarm aus, wenn der Druck außerhalb des sicheren Bereichs liegt.
  • Erkennung von Faserbrüchen: Überwacht kontinuierlich die Faserintegrität, um einen unsicheren Betrieb zu verhindern.
  • Schutz vor Überhitzung: Schaltet den Laser automatisch ab, wenn er eine übermäßige Hitze feststellt.
  • Optische und akustische Warnungen: Warnen Sie die Bediener in Echtzeit vor betrieblichen Problemen.
  • Sicherheits-Schlüsselschalter: Die Benutzung ist nur autorisiertem Personal vorbehalten.
  • Notfall-Bedienelemente: Eingebauter Notausschalter und Netzschalter zur sofortigen Abschaltung des Systems.

Rechtlicher Hinweis #

Alle Aussagen, Spezifikationen und technischen Informationen in diesem Dokument dienen nur als allgemeine Referenz. Die technischen Daten können ohne vorherige Ankündigung geändert werden. Die offizielle Produktdokumentation, die mit jedem Gerät der MA1-Serie geliefert wird, ist die einzige maßgebliche Quelle für alle technischen Details, Sicherheitsrichtlinien und Gebrauchsanweisungen. THEO übernimmt keine Haftung für etwaige Fehler oder Auslassungen in diesem Dokument und behält sich das Recht vor, seine Produkte jederzeit zu ändern.