Below is a consolidated reference table covering all current MA1 Series handheld laser welder models (MA1‑35, MA1‑45, MA1‑65, and MA1 ULTRA). These details will aid a Laser Safety Officer (LSO) or safety consultant in designing a safe Class 4 laser work environment: selecting appropriate eyewear, defining barriers/enclosures, managing ventilation, and implementing access control procedures. All data are taken from THEO’s Technical Data MA1 Series (version 1.2).

MA1 Series laserparameters en EU-veiligheidsreferenties #

Laser welding source #

Parameter MA1‑35 MA1‑45 MA1‑65 MA1 ULTRA Belangrijke EU- / veiligheidsaanwijzingen
Classificatie Class 4 near‑IR fiber laser
Conforms to IEC 60825‑1 / EN 60825‑1
Class 4 lasers demand a laser‑controlled area with door/curtain interlocks, warning signs (ISO 7010), and strict PPE. Comply with EN 60825‑4 for enclosures/guards.
Wavelength 1080 ± 10 nm
Uitgangsvermogen Up to 800W Up to 1200W Up to 1500W Up to 2000W All can be adjusted from ~10–100 % of nominal. Even at lower settings, Class 4 hazard remains.
Input power 3000 W 4800 W 6000 W 6000 W
Weld penetration, stainless steel Up to ~3.5 mm Up to ~4.5 mm Up to ~6.5 mm Up to ~8.5 mm De werkelijke penetratie hangt af van de verplaatsingssnelheid, het beschermgas en de materiaaleigenschappen.
Weld penetration, steel Up to ~3.5 mm Up to ~4.5 mm Up to ~6.5 mm Up to ~8.5 mm De werkelijke penetratie hangt af van de verplaatsingssnelheid, het beschermgas en de materiaaleigenschappen.
Weld penetration, aluminum Up to ~3.0 mm Up to ~4.0 mm Up to ~5.5 mm Up to ~6.5 mm De werkelijke penetratie hangt af van de verplaatsingssnelheid, het beschermgas en de materiaaleigenschappen.

General characteristics #

Parameter MA1‑35 MA1‑45 MA1‑65 MA1 ULTRA Belangrijke EU- / veiligheidsaanwijzingen
Power supply Single‑phase 200–240 V AC
(~26 A recommended)
Moet voldoen aan CE-vereisten onder Laagspanningsrichtlijn (2014/35/EU) en plaatselijke elektrische normen. Goede aarding is verplicht.
Bedrijfstemperatuur 0–40 °C
Relative humidity 10–85 %
Opslagtemperatuur −10–60 °C
Gewicht 29 ± 3 kg (64 lb) 38 ± 3 kg (84 lb) 39 ± 3 kg (86 lb) 42 ± 3 kg (93 lb)
Dimensions (L × H × W) 577 × 512 × 265 mm 667 × 542 × 276 mm 667 × 542 × 276 mm 667 × 542 × 276 mm
Airborne noise level Max. 85 dB(A)
Fans adjust automatically to the working condition.
For installations within the EU, comply with EN ISO 11553‑3.
Cooling, laser source Luchtgekoeld (interne ventilatoren) Zorg ervoor dat de ventilatieopeningen vrij zijn. De omgevingstemperatuur en -vochtigheid moeten binnen de gespecificeerde grenzen blijven.
Cooling, welding head Gas cooling of the fiber connector and optics

Optical parameters #

Parameter MA1‑35 MA1‑45 MA1‑65 MA1 ULTRA Belangrijke EU- / veiligheidsaanwijzingen
Operating mode Continuous‑Wave (CW) fiber laser
May be rapidly gated on/off for tack or “fish‑scale” welds
No Q‑switched or short‑pulse output. Laser is fundamentally CW, which is fully Class 4 at any power setting.
Polarisatie Random
Output at 100 % CW 750–800W 1150–1200W 1450–1500W 1900–2000W Ambient temperature 26 °C
Electro‑optical efficiency 27 % 35 % The MA1 ULTRA uses a different diode technology.
Regelbereik 10–100 % 1 %; ambient temperature 26 °C
Raw beam diameter 4.47 mm
Beam diameter at focus point 60 µm
Afwijkingshoek 29.8 mrad
Rayleigh length 2,0 mm
Duty cycle 75 % 75 % 75 % 100 % 75 % ≈ 120 s on / 40 s off
Wobble width range 0–4 mm 0–6 mm* *Available from H2/2026
Maximale modulatiefrequentie 10 kHz
Laser switch‑off delay (programmable) 0–100 ms
Short‑term power stability 2 % 100 % CW, > 1 h
Collimating lens (QCS) 50 mm Focal length of the collimating lens
Focuslens 150 mm Focal length of the focusing lens
Beam quality M² 1.3 (typ.) 100 % CW
Laser activation time (on) 50–100 µs 10–90 % power
Laser switch‑off time 50–100 µs 90–10 % output
Detectie van vezelbreuken 100 µs
Displayed power of the red pilot beam 300–1000 µW 100 % CW
NOHD 127 m 156 m 174 m 201 m Eye hazard calculation
MPE, eye (MZB) 70.7 W/m² Based on DIN EN 60825‑1
NHZ 24 m 29 m 33 m 38 m Skin hazard calculation
MPE, skin 2000 W/m² Based on DIN EN 60825‑1
Fiber diameter 20 µm
Length of the hose pack with optical fiber 4.35 m 5.6 m 5.6 m 5.6 m
Bending radius of the fiber hose pack 200 mm
Laseruitgangsconnector QCS, integrated fiber

Shielding gas, protective equipment and workplace #

Parameter MA1 Series (all models) Belangrijke EU- / veiligheidsaanwijzingen
Shielding gas Argon (Ar) @ 99.996 % purity
Nitrogen (N₂) @ 99.999 % purity
~10–16 l/min (~21–34 cfh)
Argon of stikstof helpt oxidatie en spatten te verminderen. De gastoevoer en -druk moeten voldoen aan de plaatselijke veiligheidsnormen voor gas.
Laser eye protection >1070–1075 nm → OD6+, D LB6 + IR LB8 + M LB9
>1075–1080 nm → OD6+, D LB6 + IRM LB8
>1080–1087 nm → OD6+, D LB6 + IRM LB7
Check label for wavelength and OD. Use a visor or helmet with IR filter.

PPE must meet EU Regulation 2016/425 and/or ANSI Z136.7 outside the EU.

In the EU, use EN 207 glasses for full protection or EN 208 for alignment.
Barrier / interlock Use laser‑rated enclosures or curtains. Interlock doors recommended (EN 60825‑4). Class 4 lasers require strict access control. Automatic shutdown upon unplanned entry is standard best practice.
Other PPE & clothing – Laser goggles + welding helmet (IR filter)
– Flame‑resistant outerwear/gloves (CE‑approved, e.g. EN ISO 11611 or EN ISO 11612)
Beschermt tegen directe/diffuse straling, lasboogschittering, vonken en hete spatten.
Ventilatie Local exhaust or filtration recommended (e.g., EN ISO 15012) to manage fumes and airborne particles Laser welding can produce particulates, especially on coated or galvanized metals. Proper ventilation is essential for safety and legal compliance.

T1 wire feeder #

Parameter T1 wire feeder
Power supply 24 V DC
Omgevingsomstandigheden No vibration, no bounce
Bedrijfstemperatuur 5–50 °C
Luchtvochtigheid < 90 % RH
Opslagtemperatuur −15–85 °C
Dimensions (L × H × W) 580 × 360 × 245 mm
Gewicht 13 ± 3 kg (29 lb)
Maximum wire coil weight 25 kg (55 lb)

For more in-depth specifications, recommended welding settings, and operational guidelines, see the THEO MA1 Operator Manual or contact THEO technical support.

Certificeringen en normen #

Certificering MA1 Series Harmonized standards / basis
EC Declaration of Conformity (CE) In accordance with:
Machinery Directive 2006/42/EC
Low Voltage Directive 2014/35/EU
EMC Directive 2014/30/EU
ISO 12100:2010
ISO 11553‑2:2008
EN 60204‑1:2018
EN 60825‑1:2014+A11:2021
EN IEC 61000‑6‑4:2019
EN IEC 61000‑6‑2:2019
Performance level calculation PL d (third‑party certified, SGS) ISO 13849‑1:2015
Verification of EMC compliance EN IEC 61000‑6‑2:2019
EN IEC 61000‑6‑4:2019
IP protection class IP 54
FCC Supplier’s Declaration of Conformity 47 CFR Part 15 U.S. electromagnetic compatibility
FDA verification of compliance 21 CFR Part 1040.10 U.S. laser safety requirements
Machinery Directive verification of compliance EN ISO 11553‑2:2008
EN ISO 12100:2010
EN 60204‑1:2018
EN 60825‑1:2014+A11:2021
ETL Electrical safety, compatible with UL and CSA standards

Uitgebreide veiligheidsmaatregelen #

  • LOOP Veiligheidsvergrendeling: De aanraakgevoelige toorts en werkstukklem voorkomen dat de laser per ongeluk wordt geactiveerd.
  • Extra dubbelkanaals vergrendeling: Verhoogt de veiligheid tijdens het gebruik. Maakt een externe noodstop mogelijk via de DB25-aansluiting.
  • Lastoortsschakelaar: Zorgt ervoor dat de laser alleen vuurt als hij opzettelijk wordt ingeschakeld.
  • Gasdrukdetectie: Maakt automatisch verbinding met de bedieningsschakelaar en activeert een veiligheidsalarm als de druk buiten veilige niveaus valt.
  • Detectie vezelbreuk: Bewaakt voortdurend de integriteit van de vezel om onveilige werking te voorkomen.
  • Overtemperatuurbeveiliging: Schakelt de laser automatisch uit als hij overmatige hitte detecteert.
  • Visuele en akoestische waarschuwingen: Waarschuw operators in realtime voor operationele problemen.
  • Veiligheidssleutelschakelaar: Beperkt het gebruik tot bevoegd personeel.
  • Noodbediening: E-stopknop en aan/uit-schakelaar aan boord voor onmiddellijke uitschakeling van het systeem.

Wettelijke aansprakelijkheid #

Alle verklaringen, specificaties en technische informatie in dit document zijn uitsluitend bedoeld als algemene referentie. Technische specificaties kunnen zonder voorafgaande kennisgeving worden gewijzigd. De officiële productdocumentatie die bij elke MA1 serie machine wordt geleverd is de enige gezaghebbende bron voor alle technische details, veiligheidsrichtlijnen en gebruiksinstructies. THEO aanvaardt geen aansprakelijkheid voor eventuele fouten of omissies in deze documentatie en behoudt zich het recht voor om zijn producten op elk gewenst moment te wijzigen.