THEO MA1 Series | Paramètres de fonctionnement

Below is a consolidated reference table covering all current MA1 Series handheld laser welder models (MA1‑35, MA1‑45, MA1‑65, and MA1 ULTRA). These details will aid a Laser Safety Officer (LSO) or safety consultant in designing a safe Class 4 laser work environment: selecting appropriate eyewear, defining barriers/enclosures, managing ventilation, and implementing access control procedures. All data are taken from THEO’s Technical Data MA1 Series (version 1.2).

Paramètres du laser de la série MA1 et références de sécurité de l'UE #

Laser welding source #

Paramètre MA1‑35 MA1‑45 MA1‑65 MA1 ULTRA Notes sur l'UE et la sécurité
Classification Class 4 near‑IR fiber laser
Conforms to IEC 60825‑1 / EN 60825‑1
Class 4 lasers demand a laser‑controlled area with door/curtain interlocks, warning signs (ISO 7010), and strict PPE. Comply with EN 60825‑4 for enclosures/guards.
Wavelength 1080 ± 10 nm
Puissance de sortie Up to 800W Up to 1200W Up to 1500W Up to 2000W All can be adjusted from ~10–100 % of nominal. Even at lower settings, Class 4 hazard remains.
Input power 3000 W 4800 W 6000 W 6000 W
Weld penetration, stainless steel Up to ~3.5 mm Up to ~4.5 mm Up to ~6.5 mm Up to ~8.5 mm La pénétration réelle dépend de la vitesse de déplacement, du gaz de protection et des propriétés du matériau.
Weld penetration, steel Up to ~3.5 mm Up to ~4.5 mm Up to ~6.5 mm Up to ~8.5 mm La pénétration réelle dépend de la vitesse de déplacement, du gaz de protection et des propriétés du matériau.
Weld penetration, aluminum Up to ~3.0 mm Up to ~4.0 mm Up to ~5.5 mm Up to ~6.5 mm La pénétration réelle dépend de la vitesse de déplacement, du gaz de protection et des propriétés du matériau.

General characteristics #

Paramètre MA1‑35 MA1‑45 MA1‑65 MA1 ULTRA Notes sur l'UE et la sécurité
Power supply Single‑phase 200–240 V AC
(~26 A recommended)
Doit répondre aux exigences CE en vertu de la directive sur les basses tensions (2014/35/UE) et des normes électriques locales. Une mise à la terre appropriée est obligatoire.
Température ambiante de fonctionnement 0–40 °C
Relative humidity 10–85 %
Température de stockage −10–60 °C
Poids 29 ± 3 kg (64 lb) 38 ± 3 kg (84 lb) 39 ± 3 kg (86 lb) 42 ± 3 kg (93 lb)
Dimensions (L × H × W) 577 × 512 × 265 mm 667 × 542 × 276 mm 667 × 542 × 276 mm 667 × 542 × 276 mm
Airborne noise level Max. 85 dB(A)
Fans adjust automatically to the working condition.
For installations within the EU, comply with EN ISO 11553‑3.
Cooling, laser source Refroidissement par air (ventilateurs internes) Veille à ce que les bouches d'aération ne soient pas obstruées. La température et l'humidité ambiantes doivent rester dans les limites spécifiées.
Cooling, welding head Gas cooling of the fiber connector and optics

Optical parameters #

Paramètre MA1‑35 MA1‑45 MA1‑65 MA1 ULTRA Notes sur l'UE et la sécurité
Operating mode Continuous‑Wave (CW) fiber laser
May be rapidly gated on/off for tack or “fish‑scale” welds
No Q‑switched or short‑pulse output. Laser is fundamentally CW, which is fully Class 4 at any power setting.
Polarisation Random
Output at 100 % CW 750–800W 1150–1200W 1450–1500W 1900–2000W Ambient temperature 26 °C
Electro‑optical efficiency 27 % 35 % The MA1 ULTRA uses a different diode technology.
Plage de réglage de la puissance 10–100 % 1 %; ambient temperature 26 °C
Raw beam diameter 4.47 mm
Beam diameter at focus point 60 µm
Angle de divergence 29.8 mrad
Rayleigh length 2,0 mm
Duty cycle 75 % 75 % 75 % 100 % 75 % ≈ 120 s on / 40 s off
Wobble width range 0–4 mm 0–6 mm* *Available from H2/2026
Fréquence de modulation maximale 10 kHz
Laser switch‑off delay (programmable) 0–100 ms
Short‑term power stability 2 % 100 % CW, > 1 h
Collimating lens (QCS) 50 mm Focal length of the collimating lens
Lentille de mise au point 150 mm Focal length of the focusing lens
Beam quality M² 1.3 (typ.) 100 % CW
Laser activation time (on) 50–100 µs 10–90 % power
Laser switch‑off time 50–100 µs 90–10 % output
Détection de rupture de fibre 100 µs
Displayed power of the red pilot beam 300–1000 µW 100 % CW
NOHD 127 m 156 m 174 m 201 m Eye hazard calculation
MPE, eye (MZB) 70.7 W/m² Based on DIN EN 60825‑1
NHZ 24 m 29 m 33 m 38 m Skin hazard calculation
MPE, skin 2000 W/m² Based on DIN EN 60825‑1
Fiber diameter 20 µm
Length of the hose pack with optical fiber 4.35 m 5.6 m 5.6 m 5.6 m
Bending radius of the fiber hose pack 200 mm
Connecteur de sortie laser QCS, integrated fiber

Shielding gas, protective equipment and workplace #

Paramètre MA1 Series (all models) Notes sur l'UE et la sécurité
Shielding gas Argon (Ar) @ 99.996 % purity
Nitrogen (N₂) @ 99.999 % purity
~10–16 l/min (~21–34 cfh)
L'argon ou l'azote permet de réduire l'oxydation et les éclaboussures. L'alimentation en gaz et la pression doivent respecter les normes locales de sécurité du gaz.
Laser eye protection >1070–1075 nm → OD6+, D LB6 + IR LB8 + M LB9
>1075–1080 nm → OD6+, D LB6 + IRM LB8
>1080–1087 nm → OD6+, D LB6 + IRM LB7
Check label for wavelength and OD. Use a visor or helmet with IR filter.

PPE must meet EU Regulation 2016/425 and/or ANSI Z136.7 outside the EU.

In the EU, use EN 207 glasses for full protection or EN 208 for alignment.
Barrier / interlock Use laser‑rated enclosures or curtains. Interlock doors recommended (EN 60825‑4). Class 4 lasers require strict access control. Automatic shutdown upon unplanned entry is standard best practice.
Other PPE & clothing – Laser goggles + welding helmet (IR filter)
– Flame‑resistant outerwear/gloves (CE‑approved, e.g. EN ISO 11611 or EN ISO 11612)
Protège des rayons directs/diffus, de l'éblouissement de l'arc de soudage, des étincelles et des éclaboussures chaudes.
Ventilation Local exhaust or filtration recommended (e.g., EN ISO 15012) to manage fumes and airborne particles Laser welding can produce particulates, especially on coated or galvanized metals. Proper ventilation is essential for safety and legal compliance.

T1 wire feeder #

Paramètre T1 wire feeder
Power supply 24 V DC
Conditions ambiantes No vibration, no bounce
Température ambiante de fonctionnement 5–50 °C
Humidité ambiante < 90 % RH
Température de stockage −15–85 °C
Dimensions (L × H × W) 580 × 360 × 245 mm
Poids 13 ± 3 kg (29 lb)
Maximum wire coil weight 25 kg (55 lb)

For more in-depth specifications, recommended welding settings, and operational guidelines, see the THEO MA1 Operator Manual or contact THEO technical support.

Certifications et normes

Certification MA1 Series Harmonized standards / basis
EC Declaration of Conformity (CE) In accordance with:
Machinery Directive 2006/42/EC
Low Voltage Directive 2014/35/EU
EMC Directive 2014/30/EU
ISO 12100:2010
ISO 11553‑2:2008
EN 60204‑1:2018
EN 60825‑1:2014+A11:2021
EN IEC 61000‑6‑4:2019
EN IEC 61000‑6‑2:2019
Performance level calculation PL d (third‑party certified, SGS) ISO 13849‑1:2015
Verification of EMC compliance EN IEC 61000‑6‑2:2019
EN IEC 61000‑6‑4:2019
IP protection class IP 54
FCC Supplier’s Declaration of Conformity 47 CFR Part 15 U.S. electromagnetic compatibility
FDA verification of compliance 21 CFR Part 1040.10 U.S. laser safety requirements
Machinery Directive verification of compliance EN ISO 11553‑2:2008
EN ISO 12100:2010
EN 60204‑1:2018
EN 60825‑1:2014+A11:2021
ETL Electrical safety, compatible with UL and CSA standards

Des mesures de sécurité complètes #

  • Verrouillage de sécurité LOOP: La torche tactile et la pince à pièces empêchent l'activation accidentelle du laser.
  • Verrouillage supplémentaire à deux canaux: Renforce la sécurité pendant le fonctionnement. Permet un arrêt d'urgence externe via la prise DB25.
  • Déclencheur de la torche de soudage: Assure que le laser ne se déclenche que lorsqu'il est délibérément engagé.
  • Détection de la pression du gaz: Se connecte automatiquement à l'interrupteur de commande et active une alarme de sécurité si les pressions tombent en dehors des niveaux de sécurité.
  • Détection des ruptures de fibre: Surveille en permanence l'intégrité de la fibre afin d'éviter toute opération dangereuse.
  • Protection contre la surchauffe: Arrête automatiquement le laser s'il détecte une chaleur excessive.
  • Alertes visuelles et sonores: Avertit les opérateurs des problèmes opérationnels en temps réel.
  • Interrupteur à clé de sécurité: Limite l'utilisation au personnel autorisé uniquement.
  • Commandes d'urgence: Bouton d'arrêt d'urgence et interrupteur d'alimentation embarqués pour un arrêt immédiat du système.

Avis de non-responsabilité #

Toutes les déclarations, spécifications et informations techniques contenues dans ce document sont fournies à titre de référence générale uniquement. Les spécifications techniques peuvent être modifiées sans préavis. La documentation officielle du produit livrée avec chaque machine de la série MA1 est la seule source faisant autorité pour tous les détails techniques, les directives de sécurité et les instructions d'utilisation. THEO décline toute responsabilité en cas d'erreur ou d'omission dans ce document et se réserve le droit de modifier ses produits à tout moment.

Quels sont tes sentiments ?