THEO MA1 Series | Parametry pracy

Below is a consolidated reference table covering all current MA1 Series handheld laser welder models (MA1‑35, MA1‑45, MA1‑65, and MA1 ULTRA). These details will aid a Laser Safety Officer (LSO) or safety consultant in designing a safe Class 4 laser work environment: selecting appropriate eyewear, defining barriers/enclosures, managing ventilation, and implementing access control procedures. All data are taken from THEO’s Technical Data MA1 Series (version 1.2).

Parametry lasera serii MA1 i zalecenia bezpieczeństwa UE #

Laser welding source #

Parametr MA1‑35 MA1‑45 MA1‑65 MA1 ULTRA Kluczowe uwagi UE / dotyczące bezpieczeństwa
Klasyfikacja Class 4 near‑IR fiber laser
Conforms to IEC 60825‑1 / EN 60825‑1
Class 4 lasers demand a laser‑controlled area with door/curtain interlocks, warning signs (ISO 7010), and strict PPE. Comply with EN 60825‑4 for enclosures/guards.
Wavelength 1080 ± 10 nm
Moc wyjściowa Up to 800W Up to 1200W Up to 1500W Up to 2000W All can be adjusted from ~10–100 % of nominal. Even at lower settings, Class 4 hazard remains.
Input power 3000 W 4800 W 6000 W 6000 W
Weld penetration, stainless steel Up to ~3.5 mm Up to ~4.5 mm Up to ~6.5 mm Up to ~8.5 mm Rzeczywista penetracja zależy od prędkości ruchu, gazu osłonowego i właściwości materiału.
Weld penetration, steel Up to ~3.5 mm Up to ~4.5 mm Up to ~6.5 mm Up to ~8.5 mm Rzeczywista penetracja zależy od prędkości ruchu, gazu osłonowego i właściwości materiału.
Weld penetration, aluminum Up to ~3.0 mm Up to ~4.0 mm Up to ~5.5 mm Up to ~6.5 mm Rzeczywista penetracja zależy od prędkości ruchu, gazu osłonowego i właściwości materiału.

General characteristics #

Parametr MA1‑35 MA1‑45 MA1‑65 MA1 ULTRA Kluczowe uwagi UE / dotyczące bezpieczeństwa
Power supply Single‑phase 200–240 V AC
(~26 A recommended)
Musi spełniać wymagania CE zgodnie z dyrektywą niskonapięciową (2014/35/UE) i lokalnymi normami elektrycznymi. Prawidłowe uziemienie jest obowiązkowe.
Temperatura otoczenia podczas pracy 0–40 °C
Relative humidity 10–85 %
Temperatura przechowywania −10–60 °C
Waga 29 ± 3 kg (64 lb) 38 ± 3 kg (84 lb) 39 ± 3 kg (86 lb) 42 ± 3 kg (93 lb)
Dimensions (L × H × W) 577 × 512 × 265 mm 667 × 542 × 276 mm 667 × 542 × 276 mm 667 × 542 × 276 mm
Airborne noise level Max. 85 dB(A)
Fans adjust automatically to the working condition.
For installations within the EU, comply with EN ISO 11553‑3.
Cooling, laser source Chłodzenie powietrzem (wentylatory wewnętrzne) Upewnić się, że otwory wentylacyjne są drożne. Temperatura i wilgotność otoczenia muszą mieścić się w określonych granicach.
Cooling, welding head Gas cooling of the fiber connector and optics

Optical parameters #

Parametr MA1‑35 MA1‑45 MA1‑65 MA1 ULTRA Kluczowe uwagi UE / dotyczące bezpieczeństwa
Operating mode Continuous‑Wave (CW) fiber laser
May be rapidly gated on/off for tack or “fish‑scale” welds
No Q‑switched or short‑pulse output. Laser is fundamentally CW, which is fully Class 4 at any power setting.
Polaryzacja Random
Output at 100 % CW 750–800W 1150–1200W 1450–1500W 1900–2000W Ambient temperature 26 °C
Electro‑optical efficiency 27 % 35 % The MA1 ULTRA uses a different diode technology.
Zakres regulacji mocy 10–100 % 1 %; ambient temperature 26 °C
Raw beam diameter 4.47 mm
Beam diameter at focus point 60 µm
Kąt rozbieżności 29.8 mrad
Rayleigh length 2,0 mm
Duty cycle 75 % 75 % 75 % 100 % 75 % ≈ 120 s on / 40 s off
Wobble width range 0–4 mm 0–6 mm* *Available from H2/2026
Maksymalna częstotliwość modulacji 10 kHz
Laser switch‑off delay (programmable) 0–100 ms
Short‑term power stability 2 % 100 % CW, > 1 h
Collimating lens (QCS) 50 mm Focal length of the collimating lens
Soczewka skupiająca 150 mm Focal length of the focusing lens
Beam quality M² 1.3 (typ.) 100 % CW
Laser activation time (on) 50–100 µs 10–90 % power
Laser switch‑off time 50–100 µs 90–10 % output
Wykrywanie zerwania światłowodu 100 µs
Displayed power of the red pilot beam 300–1000 µW 100 % CW
NOHD 127 m 156 m 174 m 201 m Eye hazard calculation
MPE, eye (MZB) 70.7 W/m² Based on DIN EN 60825‑1
NHZ 24 m 29 m 33 m 38 m Skin hazard calculation
MPE, skin 2000 W/m² Based on DIN EN 60825‑1
Fiber diameter 20 µm
Length of the hose pack with optical fiber 4.35 m 5.6 m 5.6 m 5.6 m
Bending radius of the fiber hose pack 200 mm
Złącze wyjściowe lasera QCS, integrated fiber

Shielding gas, protective equipment and workplace #

Parametr MA1 Series (all models) Kluczowe uwagi UE / dotyczące bezpieczeństwa
Shielding gas Argon (Ar) @ 99.996 % purity
Nitrogen (N₂) @ 99.999 % purity
~10–16 l/min (~21–34 cfh)
Argon lub azot pomagają ograniczyć utlenianie i rozpryski. Zasilanie gazem i ciśnienie muszą być zgodne z lokalnymi normami bezpieczeństwa gazowego.
Laser eye protection >1070–1075 nm → OD6+, D LB6 + IR LB8 + M LB9
>1075–1080 nm → OD6+, D LB6 + IRM LB8
>1080–1087 nm → OD6+, D LB6 + IRM LB7
Check label for wavelength and OD. Use a visor or helmet with IR filter.

PPE must meet EU Regulation 2016/425 and/or ANSI Z136.7 outside the EU.

In the EU, use EN 207 glasses for full protection or EN 208 for alignment.
Barrier / interlock Use laser‑rated enclosures or curtains. Interlock doors recommended (EN 60825‑4). Class 4 lasers require strict access control. Automatic shutdown upon unplanned entry is standard best practice.
Other PPE & clothing – Laser goggles + welding helmet (IR filter)
– Flame‑resistant outerwear/gloves (CE‑approved, e.g. EN ISO 11611 or EN ISO 11612)
Chroni przed wiązką bezpośrednią/rozproszoną, odblaskami łuku spawalniczego, iskrami i gorącymi odpryskami.
Wentylacja Local exhaust or filtration recommended (e.g., EN ISO 15012) to manage fumes and airborne particles Laser welding can produce particulates, especially on coated or galvanized metals. Proper ventilation is essential for safety and legal compliance.

T1 wire feeder #

Parametr T1 wire feeder
Power supply 24 V DC
Warunki otoczenia No vibration, no bounce
Temperatura otoczenia podczas pracy 5–50 °C
Wilgotność otoczenia < 90 % RH
Temperatura przechowywania −15–85 °C
Dimensions (L × H × W) 580 × 360 × 245 mm
Waga 13 ± 3 kg (29 lb)
Maximum wire coil weight 25 kg (55 lb)

For more in-depth specifications, recommended welding settings, and operational guidelines, see the THEO MA1 Operator Manual or contact THEO technical support.

Certyfikaty i standardy #

Certyfikacja MA1 Series Harmonized standards / basis
EC Declaration of Conformity (CE) In accordance with:
Machinery Directive 2006/42/EC
Low Voltage Directive 2014/35/EU
EMC Directive 2014/30/EU
ISO 12100:2010
ISO 11553‑2:2008
EN 60204‑1:2018
EN 60825‑1:2014+A11:2021
EN IEC 61000‑6‑4:2019
EN IEC 61000‑6‑2:2019
Performance level calculation PL d (third‑party certified, SGS) ISO 13849‑1:2015
Verification of EMC compliance EN IEC 61000‑6‑2:2019
EN IEC 61000‑6‑4:2019
IP protection class IP 54
FCC Supplier’s Declaration of Conformity 47 CFR Part 15 U.S. electromagnetic compatibility
FDA verification of compliance 21 CFR Part 1040.10 U.S. laser safety requirements
Machinery Directive verification of compliance EN ISO 11553‑2:2008
EN ISO 12100:2010
EN 60204‑1:2018
EN 60825‑1:2014+A11:2021
ETL Electrical safety, compatible with UL and CSA standards

Kompleksowe środki bezpieczeństwa #

  • Blokada bezpieczeństwa LOOP: Wrażliwy na dotyk palnik i zacisk przedmiotu obrabianego zapobiegają przypadkowej aktywacji lasera.
  • Dodatkowa blokada dwukanałowa: Zwiększa bezpieczeństwo podczas pracy. Umożliwia zewnętrzny wyłącznik awaryjny poprzez gniazdo DB25.
  • Spust palnika spawalniczego: Zapewnia, że laser strzela tylko wtedy, gdy jest celowo włączony.
  • Wykrywanie ciśnienia gazu: Automatycznie łączy się z przełącznikiem sterującym i aktywuje alarm bezpieczeństwa, jeśli ciśnienie spadnie poza bezpieczny poziom.
  • Wykrywanie uszkodzeń włókien: Stale monitoruje integralność włókien, aby zapobiec niebezpiecznej pracy.
  • Zabezpieczenie przed przegrzaniem: Automatycznie wyłącza laser, jeśli wykryje nadmierne ciepło.
  • Alerty wizualne i dźwiękowe: Ostrzeganie operatorów o problemach operacyjnych w czasie rzeczywistym.
  • Kluczowy wyłącznik bezpieczeństwa: Umożliwia korzystanie z urządzenia wyłącznie upoważnionemu personelowi.
  • Sterowanie awaryjne: Wbudowany przycisk E-stop i wyłącznik zasilania do natychmiastowego wyłączenia systemu.

Zastrzeżenie prawne #

Wszystkie oświadczenia, specyfikacje i informacje techniczne zawarte w niniejszym dokumencie mają charakter wyłącznie informacyjny. Dane techniczne mogą ulec zmianie bez powiadomienia. Oficjalna dokumentacja produktu dostarczana z każdym urządzeniem serii MA1 jest jedynym wiarygodnym źródłem wszystkich szczegółów technicznych, wytycznych dotyczących bezpieczeństwa i instrukcji użytkowania. THEO nie ponosi odpowiedzialności za jakiekolwiek błędy lub pominięcia w niniejszym dokumencie i zastrzega sobie prawo do modyfikowania swoich produktów w dowolnym momencie.

Jakie są twoje odczucia?