Série THEO MA1 | Parâmetros de funcionamento

Below is a consolidated reference table covering all current MA1 Series handheld laser welder models (MA1‑35, MA1‑45, MA1‑65, and MA1 ULTRA). These details will aid a Laser Safety Officer (LSO) or safety consultant in designing a safe Class 4 laser work environment: selecting appropriate eyewear, defining barriers/enclosures, managing ventilation, and implementing access control procedures. All data are taken from THEO’s Technical Data MA1 Series (version 1.2).

Parâmetros do laser da série MA1 e referências de segurança da UE #

Laser welding source #

Parâmetro MA1‑35 MA1‑45 MA1‑65 MA1 ULTRA Principais notas da UE / Segurança
Classificação Class 4 near‑IR fiber laser
Conforms to IEC 60825‑1 / EN 60825‑1
Class 4 lasers demand a laser‑controlled area with door/curtain interlocks, warning signs (ISO 7010), and strict PPE. Comply with EN 60825‑4 for enclosures/guards.
Wavelength 1080 ± 10 nm
Potência de saída Up to 800W Up to 1200W Up to 1500W Up to 2000W All can be adjusted from ~10–100 % of nominal. Even at lower settings, Class 4 hazard remains.
Input power 3000 W 4800 W 6000 W 6000 W
Weld penetration, stainless steel Up to ~3.5 mm Up to ~4.5 mm Up to ~6.5 mm Up to ~8.5 mm A penetração real depende da velocidade de deslocação, do gás de proteção e das propriedades do material.
Weld penetration, steel Up to ~3.5 mm Up to ~4.5 mm Up to ~6.5 mm Up to ~8.5 mm A penetração real depende da velocidade de deslocação, do gás de proteção e das propriedades do material.
Weld penetration, aluminum Up to ~3.0 mm Up to ~4.0 mm Up to ~5.5 mm Up to ~6.5 mm A penetração real depende da velocidade de deslocação, do gás de proteção e das propriedades do material.

General characteristics #

Parâmetro MA1‑35 MA1‑45 MA1‑65 MA1 ULTRA Principais notas da UE / Segurança
Power supply Single‑phase 200–240 V AC
(~26 A recommended)
Deve cumprir os requisitos CE ao abrigo da Diretiva de Baixa Tensão (2014/35/UE) e das normas eléctricas locais. É obrigatória uma ligação à terra correta.
Temperatura ambiente de funcionamento 0–40 °C
Relative humidity 10–85 %
Temperatura de armazenamento −10–60 °C
Peso 29 ± 3 kg (64 lb) 38 ± 3 kg (84 lb) 39 ± 3 kg (86 lb) 42 ± 3 kg (93 lb)
Dimensions (L × H × W) 577 × 512 × 265 mm 667 × 542 × 276 mm 667 × 542 × 276 mm 667 × 542 × 276 mm
Airborne noise level Max. 85 dB(A)
Fans adjust automatically to the working condition.
For installations within the EU, comply with EN ISO 11553‑3.
Cooling, laser source Arrefecimento por ar (ventoinhas internas) Assegurar que as aberturas de ventilação estão desobstruídas. A temperatura e a humidade ambiente de funcionamento devem manter-se dentro dos limites especificados.
Cooling, welding head Gas cooling of the fiber connector and optics

Optical parameters #

Parâmetro MA1‑35 MA1‑45 MA1‑65 MA1 ULTRA Principais notas da UE / Segurança
Operating mode Continuous‑Wave (CW) fiber laser
May be rapidly gated on/off for tack or “fish‑scale” welds
No Q‑switched or short‑pulse output. Laser is fundamentally CW, which is fully Class 4 at any power setting.
Polarização Random
Output at 100 % CW 750–800W 1150–1200W 1450–1500W 1900–2000W Ambient temperature 26 °C
Electro‑optical efficiency 27 % 35 % The MA1 ULTRA uses a different diode technology.
Intervalo de regulação de potência 10–100 % 1 %; ambient temperature 26 °C
Raw beam diameter 4.47 mm
Beam diameter at focus point 60 µm
Ângulo de divergência 29.8 mrad
Rayleigh length 2,0 mm
Duty cycle 75 % 75 % 75 % 100 % 75 % ≈ 120 s on / 40 s off
Wobble width range 0–4 mm 0–6 mm* *Available from H2/2026
Frequência máxima de modulação 10 kHz
Laser switch‑off delay (programmable) 0–100 ms
Short‑term power stability 2 % 100 % CW, > 1 h
Collimating lens (QCS) 50 mm Focal length of the collimating lens
Lente de focagem 150 mm Focal length of the focusing lens
Qualidade do feixe M² 1.3 (typ.) 100 % CW
Laser activation time (on) 50–100 µs 10–90 % power
Laser switch‑off time 50–100 µs 90–10 % output
Detecção de rutura de fibra 100 µs
Displayed power of the red pilot beam 300–1000 µW 100 % CW
NOHD 127 m 156 m 174 m 201 m Eye hazard calculation
MPE, eye (MZB) 70.7 W/m² Based on DIN EN 60825‑1
NHZ 24 m 29 m 33 m 38 m Skin hazard calculation
MPE, skin 2000 W/m² Based on DIN EN 60825‑1
Fiber diameter 20 µm
Length of the hose pack with optical fiber 4.35 m 5.6 m 5.6 m 5.6 m
Bending radius of the fiber hose pack 200 mm
Conector de saída do laser QCS, integrated fiber

Shielding gas, protective equipment and workplace #

Parâmetro MA1 Series (all models) Principais notas da UE / Segurança
Shielding gas Argon (Ar) @ 99.996 % purity
Nitrogen (N₂) @ 99.999 % purity
~10–16 l/min (~21–34 cfh)
O árgon ou o azoto ajudam a reduzir a oxidação e os salpicos. O fornecimento e a pressão do gás devem respeitar as normas locais de segurança do gás.
Laser eye protection >1070–1075 nm → OD6+, D LB6 + IR LB8 + M LB9
>1075–1080 nm → OD6+, D LB6 + IRM LB8
>1080–1087 nm → OD6+, D LB6 + IRM LB7
Check label for wavelength and OD. Use a visor or helmet with IR filter.

PPE must meet EU Regulation 2016/425 and/or ANSI Z136.7 outside the EU.

In the EU, use EN 207 glasses for full protection or EN 208 for alignment.
Barrier / interlock Use laser‑rated enclosures or curtains. Interlock doors recommended (EN 60825‑4). Class 4 lasers require strict access control. Automatic shutdown upon unplanned entry is standard best practice.
Other PPE & clothing – Laser goggles + welding helmet (IR filter)
– Flame‑resistant outerwear/gloves (CE‑approved, e.g. EN ISO 11611 or EN ISO 11612)
Protege do feixe direto/difuso, do brilho do arco de soldadura, de faíscas e de salpicos quentes.
Ventilação Local exhaust or filtration recommended (e.g., EN ISO 15012) to manage fumes and airborne particles Laser welding can produce particulates, especially on coated or galvanized metals. Proper ventilation is essential for safety and legal compliance.

T1 wire feeder #

Parâmetro T1 wire feeder
Power supply 24 V DC
Condições ambientais No vibration, no bounce
Temperatura ambiente de funcionamento 5–50 °C
Humidade ambiente < 90 % RH
Temperatura de armazenamento −15–85 °C
Dimensions (L × H × W) 580 × 360 × 245 mm
Peso 13 ± 3 kg (29 lb)
Maximum wire coil weight 25 kg (55 lb)

For more in-depth specifications, recommended welding settings, and operational guidelines, see the THEO MA1 Operator Manual or contact THEO technical support.

Certificações e normas #

Certificação MA1 Series Harmonized standards / basis
EC Declaration of Conformity (CE) In accordance with:
Machinery Directive 2006/42/EC
Low Voltage Directive 2014/35/EU
EMC Directive 2014/30/EU
ISO 12100:2010
ISO 11553‑2:2008
EN 60204‑1:2018
EN 60825‑1:2014+A11:2021
EN IEC 61000‑6‑4:2019
EN IEC 61000‑6‑2:2019
Performance level calculation PL d (third‑party certified, SGS) ISO 13849‑1:2015
Verification of EMC compliance EN IEC 61000‑6‑2:2019
EN IEC 61000‑6‑4:2019
IP protection class IP 54
FCC Supplier’s Declaration of Conformity 47 CFR Part 15 U.S. electromagnetic compatibility
FDA verification of compliance 21 CFR Part 1040.10 U.S. laser safety requirements
Machinery Directive verification of compliance EN ISO 11553‑2:2008
EN ISO 12100:2010
EN 60204‑1:2018
EN 60825‑1:2014+A11:2021
ETL Electrical safety, compatible with UL and CSA standards

Medidas de segurança abrangentes #

  • Bloqueio de segurança LOOP: A tocha sensível ao toque e o grampo da peça de trabalho evitam a ativação acidental do laser.
  • Bloqueio adicional de canal duplo: Aumenta a segurança durante o funcionamento. Permite uma paragem de emergência externa através da tomada DB25.
  • Gatilho da tocha de soldadura: Garante que o laser só dispara quando é ativado deliberadamente.
  • Deteção de pressão de gás: Liga-se automaticamente ao interrutor de controlo e ativa um alarme de segurança se as pressões ultrapassarem os níveis de segurança.
  • Deteção de quebra de fibra: Monitoriza continuamente a integridade da fibra para evitar um funcionamento inseguro.
  • Proteção contra sobreaquecimento: Desliga automaticamente o laser se detetar calor excessivo.
  • Alertas visuais e sonoros: Avisa os operadores de problemas operacionais em tempo real.
  • Chave de segurança: Restringe a utilização apenas a pessoal autorizado.
  • Controlos de emergência: Botão de paragem de emergência e interrutor de alimentação integrados para encerramento imediato do sistema.

Aviso legal #

Todas as declarações, especificações e informações técnicas contidas neste documento são fornecidas apenas para referência geral. As especificações técnicas estão sujeitas a alterações sem aviso prévio. A documentação oficial do produto que acompanha cada máquina da Série MA1 é a única fonte autorizada para todos os detalhes técnicos, diretrizes de segurança e instruções de utilização. THEO não assume qualquer responsabilidade por quaisquer erros ou omissões aqui contidos e reserva-se o direito de modificar os seus produtos em qualquer altura.

Quais são os seus sentimentos